美國 CANNON 產品 |
Glass Capillary
Viscometers : Zeitfuchs |
Transparent with
Round Holder |
Calibrated ZTC-RO Series and
uncalibrated ZTU-RO. For measurement of kinematic viscosity of transparent
Newtonian liquids according to ASTM D 445 and ISO 3104. |
 |
Specifications for Zeitfuchs®
Transparent & Cross-Arm Viscometers |
Size |
Approx. constant cSt/s |
Range centistokes* |
1 |
0.003 |
0.6 to 3 |
2 |
0.01 |
2 to 10 |
3 |
0.03 |
6 to 30 |
4 |
0.1 |
20 to 100 |
5 |
0.3 |
60 to 300 |
6 |
1.0 |
200 to 1000 |
7 |
3.0 |
600 to 3000 |
8 |
10 |
2000 to 10000 |
9 |
30 |
6000 to 30000 |
10 |
100 |
20000 to 100000 |
|
|
Transparent with
Rectangular Holder |
Calibrated ZTC-RE Series and
uncalibrated ZTU-RE Series. For measurement of kinematic viscosity of
transparent Newtonian liquids according to ASTM D 445 and ISO 3104. |
 |
Specifications for Zeitfuchs®
Transparent & Cross-Arm Viscometers |
Size |
Approx. constant cSt/s |
Range centistokes* |
1 |
0.003 |
0.6 to 3 |
2 |
0.01 |
2 to 10 |
3 |
0.03 |
6 to 30 |
4 |
0.1 |
20 to 100 |
5 |
0.3 |
60 to 300 |
6 |
1.0 |
200 to 1000 |
7 |
3.0 |
600 to 3000 |
8 |
10 |
2000 to 10000 |
9 |
30 |
6000 to 30000 |
10 |
100 |
20000 to 100000 |
|
|
Cross-Arm
Viscometers |
For measurement of kinematic
viscosity of transparent and opaque Newtonian liquids according to ASTM D 445
and ISO 3104. Specifications conform to ASTM D 446 and ISO 3105. |
 |
Specifications for Zeitfuchs®
Transparent & Cross-Arm Viscometers |
Size |
Approx. constant cSt/s |
Range centistokes* |
1 |
0.003 |
0.6 to 3 |
2 |
0.01 |
2 to 10 |
3 |
0.03 |
6 to 30 |
4 |
0.1 |
20 to 100 |
5 |
0.3 |
60 to 300 |
6 |
1.0 |
200 to 1000 |
7 |
3.0 |
600 to 3000 |
8 |
10 |
2000 to 10000 |
9 |
30 |
6000 to 30000 |
10 |
100 |
20000 to 100000 |
|
|
Crossarm with Round
Holder |
For measurement of kinematic
viscosity of transparent and opaque Newtonian liquids according to ASTM D 445
and ISO 3104. Specifications conform to ASTM D 446 and ISO 3105. |
 |
Specifications for Zeitfuchs®
Transparent & Cross-Arm Viscometers |
Size |
Approx. constant cSt/s |
Range centistokes* |
1 |
0.003 |
0.6 to 3 |
2 |
0.01 |
2 to 10 |
3 |
0.03 |
6 to 30 |
4 |
0.1 |
20 to 100 |
5 |
0.3 |
60 to 300 |
6 |
1.0 |
200 to 1000 |
7 |
3.0 |
600 to 3000 |
8 |
10 |
2000 to 10000 |
9 |
30 |
6000 to 30000 |
10 |
100 |
20000 to 100000 |
|
|
Crossarm RE |
For measurement of kinematic
viscosity of transparent and opaque Newtonian liquids according to ASTM D 445
and ISO 3104. Specifications conform to ASTM D 446 and ISO 3105. |
 |
Specifications for Zeitfuchs®
Transparent & Cross-Arm Viscometers |
Size |
Approx. constant cSt/s |
Range centistokes* |
1 |
0.003 |
0.6 to 3 |
2 |
0.01 |
2 to 10 |
3 |
0.03 |
6 to 30 |
4 |
0.1 |
20 to 100 |
5 |
0.3 |
60 to 300 |
6 |
1.0 |
200 to 1000 |
7 |
3.0 |
600 to 3000 |
8 |
10 |
2000 to 10000 |
9 |
30 |
6000 to 30000 |
10 |
100 |
20000 to 100000 |
|
|